All India Waterproofing Co.

Established in 1983

Seal Roof
 
 
 
 
 
 
 
 
 
 
 
 
FLOOR, WALLS OF BATHROOMS / TOILETS ( WATER CLOSERS AND KITCHEN MORIS)
 
The new Bathrooms/Toilets etc. are treated with our "Surface" method which starts directly over the R.C.C. Slab. The internal wall shall be plastered leaving a space of about 600mm (2 feet) from floor level.

Before the commencement of our work all chiseling / cutting in the floor and wall shall be done by the Plumber.
  1. We shall then put a layer of "Sealroof" plaster of about 3/4" in which stone aggregate of 15mm to 20mm nominal size will be embedded/fixed by hand at random (the treatment shall then be cured for at least 24 hours.
     
  2. We shall now again provide a layer of "Sealroof" waterproof plaster of about 1/2" above the stone aggregate. The treatment shall be carried on the side of sunken slab and side walls up to 600mm above floor level. The thickness of the treatment on the walls will be about 3/4" (The treatment shall then be cured for at least 24 hours).
     
  3. Now the plumber shall finish all his plumbing work i.e. laying and fixing of pipes, nahani traps, pans etc. without any further breaking or disturbing our treatment.
 
 
  • R.C.C. Slab & side of sunken slab.
     
  • Stone aggregate fixed in cement mortar by hand cement mortar (1:4)
     
  • Waterproof plaster in cement mortar (1:4)
     
  • Brick Bat fixed in cement mortar (1:4) rough finish
Note: As soon as waterproof plaster in finished the owner shall provide all provide all pipes & fittings including fixing of w.c. pan.
 
 
  1. After plumbing work, we shall fill in the depression (sunken) portion with our brick-bat coba method (Brick-bat fixed in cement mortar) up to required level. (The treatment shall then be cured for at least 24 hours).
     
  2. We shall now provide our "Sealroof" waterproof plaster of about 1/2" above the brick bat layer, which shall be finished rough suitable to receive tiles to be laid by owners.
Note:
 
  1. The rates are quoted separately for waterproof plaster as one item and filling the sunken portion as second item. No deduction in the floor and wall area for pans and other fittings and fixture are made in the measurement.
     
  2. In the case of existing toilets etc. the existing treatment including filling in the depression and tilling on the floor and on the walls up to 600mm shall be removed by the plumber/owner and rectify or replace all the defective plumbing etc. before we commence our work.
 
  • R.C.C. Slab & side of sunken slab.
     
  • Stone aggregate fixed in cement mortar by hand cement mortar (1:4)
     
  • Waterproof plaster in cement mortar (1:4)
     
  • Brick Bat fixed in cement mortar (1:5)
     
  • Top finish in cement mortar (1:4) rough finish.
 
Note: As soon as waterproof plaster in finished the owner shall provide all provide all pipes & fittings including fixing of nahani trap.